Instant adhesives
Instant component, low viscosity, metal bonding
A low viscosity, methyl instant adhesive which is particularly suited to bonding of metal substrates.
All marks used are trademarks and/or registered trademarks of Henkel and its affiliates in the US, Germany, and elsewhere.
233978
-
{{#data}}
{{#distributor.isVisible}}
{{#distributor.isExpanded}}
-
{{^distributor.unique}}
{{/distributor.unique}}
{{#distributor.onShelf}} {{#distributor.withSpecialPrice}} {{distributor.prices.specialWithSymbol}}
{{distributor.prices.regularWithSymbol}}
{{#distributor.withoutSpecialPrice}} {{distributor.prices.regularWithSymbol}}
{{#distributor.anyInStock}} In stock {{#distributor.notInStock}} Out of stock {{#distributor.notOnShelf}} {{^distributor.notInStock}} {{#distributor.onShelf}} All available stock is already in cartYou have reached the maximum order quantity availableFor industrial use only. Not intended for consumer sale or use.
Large volume or special order?
{{#distributor.notOnShelf}} {{/distributor.notInStock}}{{#distributor.notInStock}} {{#distributor.onShelf}} {{#distributor.notInStock}} {{/distributor.onShelf}}There was a problem with your request. Please try again or contact us directly. You will receive an email notification when product is back in stock.You will not receive an email notification when product is back in stock.
{{/distributor.isExpanded}}
{{^distributor.isExpanded}}
{{/distributor.isExpanded}}
{{/distributor.isVisible}}
{{/data}}
- Description
- Technical specification
- Ratings & reviews
- Question & answer
LOCTITE® 430 is a low viscosity, general purpose instant adhesive that is particularly suited to bonding metal substrates. It has been qualified to Commercial Item Description A-A-3097 (this is a regional approval).
-
Particularly suited to bonding of metal substrates
-
Low viscosity
-
Qualified to Commercial Item Description A-A-3097 (regional approval)
- Product category:
- Instant adhesives
Technologies:
-
Cyanoacrylate
- Applications:
- Bonding close fitting parts
- Color:
- Clear
- Cure type:
- Moisture cure
- Fixture time:
- 30.0 sec.
- Full cure time, @ 25.0 °C:
- 24.0 hr.
- Key characteristics:
- General purpose,Viscosity: low viscosity
- Number of components:
- 1 part
- Physical form:
- Liquid
- Recommended for use with:
- Metal,Plastic,Rubber
- Specific gravity, @ 25.0 °C:
- 1.1
- Viscosity, Brookfield - LVF, @ 25.0 °C:
- 70.0 mPa·s (cP) - 110.0 mPa·s (cP)
- Viscosity, cone & plate, @ 25.0 °C:
- 60.0 mPa·s (cP) - 90.0 mPa·s (cP)
How to use
It is recommended to use the correct LOCTITE® cleaner for the surface to be bonded (such as LOCTITE® SF 7070) to degrease and clean surfaces prior to applying the adhesive.
To improve adhesion on difficult to bond plastic surfaces, apply LOCTITE® SF 770 to the bond area by brushing or dipping. Avoid applying excess primer. Allow the primer to dry.
If cure speed is too slow, use activator LOCTITE® SF 7452 or LOCTITE® SF 7455 (see cure speed vs activator graph in TDS). Apply activator to one bond surface by spray, brush or dipping (not primed surfaces). Allow the activator to dry.
Apply adhesive onto one side/part.
Assemble parts immediately. The parts should be accurately located as the short fixture time leaves little opportunity for adjustment. Bond should be held or clamped until the adhesive has fixtured.Hint: if necessary, excess product can be cured by activator LOCTITE® SF 7452. Spray or drop activator onto excess product.
For precise dispensing of small amounts of adhesive, the use of dispensing needles is recommended.
FAQ
This is a result of stress cracking. Uncured liquid CA remaining on some plastic substrate (such as polycarbonate, acrylic, and polysulfone) in a stressed condition may cause the formation of cracks in the plastic. Some remedies for avoiding/minimizing stress cracking are closing the bond joint quickly, use reinforced grades of plastic, anneal parts, or speed the cure of the CA with accelerator (or light for light curing CA products only).
This is called blooming. This often occurs when there is an excessive amount of product being applied. To avoid blooming, use proper ventilation, less product, lower humidity, use a primer/accelerator, or a low bloom product.
Yes, CA’s should be stored in the refrigerator prior to opening, but DO NOT refrigerate them once they have already been opened. After opening, CA's should be used within 30 days for best performance.
All necessary H&S measures and PPE (personal protection equipment) requirements can be found on the product material safety data sheet, all of which are available via our website.
Henkel has several products available with varying levels of NSF® approval, amongst others. Please contact the Henkel sales or technical teams with your requirements.
-
{{#data}}
{{#distributor.isVisible}}
{{#distributor.isExpanded}}
-
{{^distributor.unique}}
{{/distributor.unique}}
{{#distributor.onShelf}} {{#distributor.withSpecialPrice}} {{distributor.prices.specialWithSymbol}}
{{distributor.prices.regularWithSymbol}}
{{#distributor.withoutSpecialPrice}} {{distributor.prices.regularWithSymbol}}
{{#distributor.anyInStock}} In stock {{#distributor.notInStock}} Out of stock {{#distributor.notOnShelf}} {{^distributor.notInStock}} {{#distributor.onShelf}} All available stock is already in cartYou have reached the maximum order quantity availableFor industrial use only. Not intended for consumer sale or use.
Large volume or special order?
{{#distributor.notOnShelf}} {{/distributor.notInStock}}{{#distributor.notInStock}} {{#distributor.onShelf}} {{#distributor.notInStock}} {{/distributor.onShelf}}There was a problem with your request. Please try again or contact us directly. You will receive an email notification when product is back in stock.You will not receive an email notification when product is back in stock.
{{/distributor.isExpanded}}
{{^distributor.isExpanded}}
{{/distributor.isExpanded}}
{{/distributor.isVisible}}
{{/data}}