As AI workloads surge and ultra-high-speed networking becomes the new standard, hardware design teams across telecom and data center sectors face an increasingly urgent challenge: cooling is no longer a peripheral concern—it’s a critical design constraint shaping system architecture. With power densities climbing rapidly, traditional air cooling methods are nearing their physical and thermodynamic limits, pushing engineers to fundamentally rethink thermal strategies from chip to rack level.

robotic arm ai holding computer processor

The rising heat load: cooling as a system-level driver

Modern high-performance systems often feature components with Thermal Design Power (TDP) exceeding 400 watts. At the rack scale, cumulative heat loads can surpass 30 kilowatts—numbers that would have been unthinkable just a few years ago. These figures reflect denser, faster, and more power-hungry silicon.

Traditional air cooling, which relies on forced airflow, is rapidly approaching its physical capacity due to limits in heat transfer coefficients and airflow velocity without creating excessive noise or power consumption. Even the most aggressive air-cooling setups struggle to maintain safe operating temperatures, especially in tightly packed racks.

This reality is driving a paradigm shift toward liquid cooling solutions. Once confined to niche high-performance computing (HPC) environments, liquid cooling is now rapidly becoming mainstream. Beyond merely reducing temperatures, liquid cooling fundamentally changes system architecture, fluid dynamics, and engineering approaches.

Beyond temperature: the broad impact of liquid cooling

Liquid cooling introduces a new set of complex design considerations:

  • Mechanical stress: systems must now accommodate increased pressure loads from fluid flow, including pressure pulsations and vibrations. This affects component packaging, seals, and connector reliability, requiring materials and designs that withstand sustained hydraulic stress without leakage or mechanical failure.
  • Material demands: components and interconnects must endure rigorous thermal cycling and vibrations without loss of mechanical integrity or microstructural damage. Selecting materials with compatible coefficients of thermal expansion (CTE), high fatigue resistance, and chemical compatibility with coolants is critical.
  • Reliability concerns: integrating liquid cooling hardware introduces new failure modes—such as leaks, corrosion, and biofouling—which demand careful coolant chemistry management, robust sealing techniques, and proactive maintenance strategies.
  • Layout and serviceability: cooling channels, cold plates, and heat exchangers necessitate reimagined system layouts, impacting chassis design, modularity, and ease of maintenance. Engineers must balance optimal thermal pathways with accessibility for servicing and replacement.
  • Condensation and compliance: managing moisture and preventing condensation require rigorous insulation and environmental controls. Additionally, meeting evolving regulatory standards on refrigerants and coolant materials adds complexity to design and manufacturing.

These considerations illustrate that thermal management no longer operates in isolation—it intersects deeply with mechanical design, electrical performance, and materials engineering.

Engineering questions at the forefront

People in the innovation center

Discussions with hardware design teams highlight several critical engineering challenges:

  • How can systems maintain mechanical robustness under combined pressure stresses, thermal cycling, and vibration over operational lifetimes?
  • Which material combinations optimize thermal conductivity, mechanical strength, chemical resistance, and manufacturability?
  • What testing and validation protocols ensure system reliability when liquid cooling hardware is integrated?
  • How can systems be designed for easy maintenance, quick leak detection, and minimal downtime in liquid-cooled environments?

Addressing these questions early in the design process is vital to avoid costly redesigns, failures, and operational disruptions.

Embracing a new design paradigm

Thermal innovation has evolved from a reactive afterthought to a co-equal driver in system design. This shift represents one of the most significant changes in hardware development over recent years—and it’s accelerating rapidly.

Success in this new era depends on early, cross-disciplinary collaboration among thermal, mechanical, electrical, and materials engineering teams. Aligning these disciplines from the earliest stages of the design cycle optimizes system performance, reliability, and manufacturability.

Ultimately, these evolving cooling demands are reshaping the entire infrastructure stack—from chip packaging and board-level layout to rack-level architecture—driving new standards for power density, efficiency, and serviceability. As data centers and telecom networks advance toward next-generation performance, mastering thermal innovation will be a foundational pillar of future success.

Resources

  • This is a futuristic concept image of a server in a data center.

    Phase change interface materials for next-gen data center ICs

    This case study looks at how low-pressure, low thermal impedance, phase change thermal interface material provides a much-needed solution for next-gen data center ICs.

    10 min.

  • This image displays a micro thermal interface coating on a pluggable optical transceiver.

    Durable TIM coating reduces heat and improves data center switch performance

    This case study looks at how durable, thin thermal interface coating reduces heat and improves data center switch performance.

    10 min.

  • This is the frozen computer chip in a block of solid ice

    The heat is on

    Today, network performance, reliability, and durability are critical to datacom and telecom performance around the world. And when network performance is largely determined by power and cooling, the role of thermal management is only going to increase.
  • This image shows city view of San Francisco

    Look small to go big

    In today’s world of unprecedented network and infrastructure expansion, the need for increased performance and stability is accelerating. This rapid expansion is further challenged by the need to process more data at faster speeds while also accommodating emerging technology developments.
  • This is an image of a network cable with fiber optical background

    The 2023 data center pulse report

    With an insatiable demand for faster networking speeds and throughput performance within the data center, 800 Gigabit Ethernet (GbE) is gaining momentum as the next big trend in networking to provide capacity to ever-growing customer demands.
  • This is an image of a man in a data center bending down

    The 2024 data center pulse report

    The influence of innovation and technology on the need to transition from 800G to 1.6T.

Looking for solutions? We can help

Our experts are here to learn more about your needs.

  • A female call-center employee smiling and wearing a headset while working in an office.

    Request a consultation

  • LOCTITE 263 Threadlocker - Application on Bolt

    Request a sample

  • A black female employee scans packages in a warehouse. In the foreground there is the woman with the yellow scanner, in the background scaffolding can be seen.

    Submit an order request

Looking for more support options?

Our support center and experts are ready to help you find solutions for your business needs.