Thermal gap fillers
Blue, 2-part, silicone-free gap filler
A blue, 2-part, silicone-free gap filler for high-throughput assembly applications.
All marks used are trademarks and/or registered trademarks of Henkel and its affiliates in the US, Germany, and elsewhere.
- Description
- Technical specification
- Ratings & reviews
- Question & answer
BERGQUIST GAP FILLER TGF 3000SF is a 2-part silicone-free gap filler for thermal management on high-throughput, silicone-sensitive assembly applications such as power storage devices and charging equipment. After mixing, this blue gap filler maintains low compression stress during assembly, cures at room temperature and offers 3.0 W/m-K thermal conductivity.
-
Silicone-free
-
Service/operating temperature: -40°C to 100°C (-40°F to 212°F)
-
Room temperature curing
-
High thermal conductivity
- Product category:
- Thermal gap fillers
Technologies:
-
Thermal management, standard viscosity liquids
FAQ
Due to the thixotropic characteristics of most gap filler materials, special consideration should be given to the test method(s) used to determine viscosity of these materials. Because the material viscosity is dependent on shear rate, different measurement equipment testing under varying shear rates will produce varied viscosity readings. When comparing apparent viscosities of multiple materials, it is important to ensure that the data was generated using the same test method and test conditions (therefore the same shear rate). Test methods and conditions for BERGQUIST® products are noted in the individual Technical Data Sheets.
Two-part gap filler systems begin curing once the two components are mixed together. Henkel defines the pot life (working life) of a two-part system as the time for the viscosity to double after parts A and B are mixed. Henkel defines the cure time of a two-part material as the time to reach 90 percent cure after mixing. Two-part gap filler materials cure at room temperature 77°F (25°C), or cure time can be accelerated with exposure to elevated temperatures.
Henkel does not advocate using gap filler products beyond the recommended shelf life and is unable to recertify material that has expired. In order to ensure timely use of product, Henkel recommends a first-in-first-out (FIFO) inventory system.
Unless otherwise indicated on Technical Data Sheets,2-part gap filler products should be stored in the original sealed container in a climate-controlled environment at or below 77°F/25°C and 50% relative humidity. If stored at reduced temperatures, materials should be placed at room temperature and allowed to stabilize prior to use. Unless otherwise noted, all cartridges and tubes should be stored in Henkel-defined packaging with the nozzle end down.
Short periods of time above the recommended storage temperature, such as during shipping, have not been shown to affect the material characteristics.
Although gap filler is not designed as a structural adhesive, when cured, it has a low level of natural tack, which will allow the material to adhere mildly to adjacent components. This aids in keeping the material in the interface throughout repeated temperature cycling and eliminates pump-out from the interface.
In many cases, gap filler can be reworked. The ease of rework is highly dependent on the topography of the application as well as the coverage area.
Two-part materials are available in several standard dual cartridge sizes including 50 cc (25 cc each of parts A and B) and 400 cc (200 cc each of parts A and B). Gap filler products are also available in kits of 1200 cc (two stand-alone 600 cc containers, one of each part) and 10-gallon (two 5-gallon pails, one of each part) sizes for higher volume production. Other special and custom container sizes are available upon request.
Disposable plastic static mixing nozzles are used to mix parts A and B together at the desired ratio. Static mixers can be attached to the ends of cartridges or mounted on automated dispensing equipment. They are reliable, accurate and inexpensive to replace after extended down times. Unless otherwise indicated, mixing nozzles with a minimum of 21 mixing elements are recommended to achieve proper mixing.
Two-part materials should be mixed to the stated mix ratio by volume within a +/-5% tolerance to ensure proper material characteristics. If light-colored streaks or marbling are present in the material, there has been inadequate mixing. Henkel recommends purging newly tapped containers through the static mixer until a uniform color is achieved. In order to ensure consistent material characteristics and performance, BERGQUIST® two-part systems are to be used with matching part A and B lot numbers.
Henkel can provide manual or pneumatic applicator guns for products supplied in dual cartridge form. Gap filler supplied in high volume container kits can be dispensed via automated dispensing equipment for high speed in-line manufacturing. Henkel and our other experienced automated dispensing equipment partners can further assist our customers in creating an optimized dispensing process. For information regarding dispensing equipment, contact your local Henkel representative. For some materials, screen or stencil application may be an option and should be evaluated on a case by case basis.
Although not common, it is possible to encounter materials that can affect the cure of a two-part gap filler. A list of general categories of compounds that may inhibit the rate of cure or poison the curing catalyst in gap filler products is available to help assist with material compatibility evaluation. Please contact your local Henkel representative for more details.